11
09/03/2011
If you are connecting more than two expansion chassis together, you can continue to expand
the gen lock link to further downstream chassis by fitting a H-link board into the first slot of the
first expansion chassis and by connecting a Gen-lock cable from the S-Link board directly into
the H-Link card in the expansion chassis, whilst at the same time connecting the H-Link
output to the next Image 4 graphics card. See the following picture as an example. In this way
you can create very large systems and maintain the gen locking capability between all Image
4 graphics cards.